Connecting the Gateway Pines buildings with OS2 fiber in Pleasant Grove, Utah

At Gateway Pines in Pleasant Grove, Utah, a carrier serving a new tenant needs a way to reach that tenant’s suite. 1GC connected the two buildings with OS2 single-mode fiber and ran fiber to the network closet in every suite. We built the route with conduit, roughly 700 feet of orange corrugated innerduct, and two equipment racks.

Building the pathway between buildings

The route had two layers. The larger conduit formed the passage between buildings. Inside it, corrugated innerduct gave the OS2 fiber its own protected channel. The flexible tubing arrived on a spool so the crew could feed it into the route from an access point. The approximately 700-foot figure describes the innerduct we installed across the job.

Crew beside a spool of orange corrugated innerduct
At the open handhole, the crew fed orange tubing from a spool into the conduit.
Orange innerduct laid out along the building walkway
A length of innerduct laid out beside the building shows how the flexible tubing handles changes in direction.

Inside the handhole

The handhole is an access box in the ground. With its cover lifted, the conduit opening and the smaller orange ducts are visible together. From the surface, the crew could reach this junction while working on the pathway. Once the cover is back in place, very little of this part of the installation is visible.

Two crew members working at the open handhole
The crew worked at the handhole opening with the innerduct within reach.
Orange innerduct emerging from gray conduit inside the handhole
Looking down into the box, the orange tubing is visible at the mouth of the gray conduit.

Bringing the pathway indoors

At the building entrance, the work shifted from feeding duct outside to bringing it up the interior wall. In the first photo below, a technician works at floor level. In the next, the orange bends are visible below a wall-mounted rack. Together the views show the transition that a finished rack photograph alone would miss.

Technician handling orange innerduct at the interior wall
Working the innerduct at the building entrance.
Orange innerduct and gray conduit below a wall-mounted rack
The exposed bends show where the fiber pathway meets the equipment location.

Two racks and the fiber connections

A carrier can install its equipment in a rack and patch directly to the fiber serving an individual suite. At the far end, the fiber reaches the suite’s intermediate distribution frame (IDF), the location where the tenant’s network connects. This gives the carrier an existing path to the customer when it is time to turn up service.

Across the two panels, the crew installed approximately 36 LC connectors, with about 24 on one panel and 12 on the other. The close-up below shows the patch connections a technician works with when connecting a suite.

Finished wall-mounted rack with an LC fiber panel behind the glass and orange innerduct below
The finished Gateway Pines rack has room for carrier equipment above the LC patch panel. Orange innerduct rises from the conduit below.
Fiber leads routed across a panel with blue ports
The fiber panel brings individual connections together at the rack.

Planning a connection between buildings? Explore our structured cabling and fiber services, see more Wasatch Front installations, or request a site survey.